Page 198 - Softbound_Edition_19_en
P. 198

Solenoid operated spool valve



                                                                                                                                   Solenoid operated spool valve, intrinsically safe
                                                                                                                                                                                        NG4-Mini
                                                                                                                                   Flange construction                                  Wandfluh standard
                                                                                                                                    ◆  4/2-way impulse valve
                                                                                                                                    ◆  4/3-way with spring centred mid position                         Ex ia I Ma
                                                                                                                                    ◆  4/2-way with spring reset                                        Ex ia II C T5 / T6 Ga
                                                                                                                                    ◆  Q  = 20 l/min                                    xII 1 G Ex ia II C T6, T5
                                                                                                                                       max
                                                                                                                                    ◆  p  = 350 bar                                     xI M1  Ex ia I Ma
                                                                                                                                       max




                                                                                                                                   DESCRIPTION                                          APPLICATION
                                                                                                                                   Direct  operated  solenoid  spool  valve  with  4  connections  in  5   These  valves  are  suitable  for  applications  in  explosion-hazard
                                                                                                                                   chamber design. With the solenoids deenergised, the spool is held   areas, open cast and also in mines.  Spool valves are mainly used for
                                                                                                                                   in the center position by the spring (4/3), or switched back to the   controlling direction of movement and stopping of hydraulic cylin-
                                                                                                                                   offset position (4/2). With the impulse spool (4/2), the spool is held   ders and motors. The direction of movement is determined by the
                                                                                                                                   in the switching position by the detent. Intrinsic safety is achie-  position  of  the  spool  and  its  symbol.  Miniature  values  are  used


                                                                                                                                   ved by limiting the electric energy in the solenoid circuit by means   where both, reduced dimensions and weight are important.

                                                                                                                                   of a separate intrinsically safe power supply. Therewith sparking
                                                                                                                                   is prevented from forming.






                                                                                                                                   CERTIFICATES                                         ACTUATION
                                                                                                                                                        Surface           Mining         Actuation          Switching solenoid, wet pin push type,
                                                                                                                                                       gas and dust                                         pressure tight
                                                                                                                                    ATEX                   x                x            Execution          M.Z45 (Data sheet 1.1-185) rotatable in
                                                                                                                                                                                                            steps of 90 ° and easy exchangeable
                                                                                                                                    IECEx                  x                x
                                                                                                                                                                                         Connection         ◆  Cable gland for cable Ø 6,5… 12 mm,
                                                                                                                                   The certificates can be found on www.wandfluh.com
                                                                                                                                                                                                              two phase conductors +/- as well as
                                                                                                                                                                                                              one ground conductor
                                                                                                                                                                                                            ◆  Connector socket EN 175301 – 803




                                                                                                                                   SYMBOL

                                                                                                                                              AB3                     AB1                    AB2
                                                                                                                                             A B                        A B               A B
                                                                                                                                        a     b                     a    b                a     b
                                                                                                                                    a                b         a               b      a                b
                                                                                                                                             P T                        P T               P T

                                                                                                                                             ACB                      AC1                    CB2
                                                                                                                                             A B                        A B                A B
                                                                                                                                         a    o    b                a     b                 a   b
                                                                                                                                    a                    b     a               b      a                b
                                                                                                                                             P T                        P T                P T

                                                                                                                                             ADB                      AD1                    DB2
                                                                                                                                             A B                        A B               A B
                                                                                                                                              o                           b                 a
                                                                                                                                         a         b                a                           b
                                                                                                                                    a                    b    a                b      a                b
                                                                                                                                             P T                        P T               P T




                                                                                                                                                       www.wandfluh.com  Illustrations are not binding  Data subject to change  1/4  Edition: 19 26  1.3-28 E
   193   194   195   196   197   198   199   200   201   202   203