Solenoid operated spool valve
                                                                                     Solenoid operated spool valve


            ELECTRICAL SPECIFICATIONS                            SURFACE TREATMENT
             Protection class   IP65 / 66 / 67                   -The valve body, the cover and the socket head screws are made of
             Relative duty factor  100 % DF                      stainless steel
             Switching frequency  12'000 / h                     -The slip-on coil and the armature tube are zinc nickel coated
                                                                 Optionally K10:
             Voltage tolerance  ± 10 % with regard to nominal voltage  -The coil is made of stainless steel
             Standard nominal   12 VDC, 24VDC, 115 VAC, 230 VAC
             voltage            AC = 50 to 60 Hz ± 2 %, with built-in   SEALING MATERIAL
                                two-way rectifier
             Standard nominal   9 W, 15 W, 17 W                  NBR or FKM (Viton) as standard, choice in the type code
             power                                               INBETRIEBNAHME
             Temperature class  Nominal power 9 W: T1…T6
                                Nominal power 15 W / 17 W: T1…T4  Attention!    The solenoid coil must only be put into operation, if the
                                                                          requirements of the operating instructions supplied are
            Note!    Other electrical specifications see data sheet 1.1-183,   observed to their full extent. In case of non-observance,
                     1.1-183S and 1.1-184                                 no liability can be assumed.



            PERFORMANCE SPECIFICATIONS
            Oil viscosity u = 30 mm /s
                             2
             p = f (Q)  Performance limits                        p = f (Q)  Performance limits L9
                       Measured with nominal voltage -10%                   Measured with nominal voltage -10%
                       at 50 °C (steady-state temperature)                  at 40 °C (steady-state temperature)
                                                                            Execution L9 90 °C on request

                p [bar]               AB1 / AB2  ADB ACB AB3/BEA     p [bar]                      ADB  ACB  AB3
               350  K4196                                          350  K4197
               300                                                 300
               250                                                 250                   AB1 / AB2
               200                                                 200
               150                                                 150
               100                                                 100
               50                                                   50
                0                                                    0
                 0      10     20     30     40    50  Q [l/min]      0     5    10    15    20   25    30  Q [l/min]


             Δp = f (Q)  Pressure drop volume flow characteristic                        Volume flow direction
                       per control edge                           Symbol         P-A    P-B     P-T    A-T    B-T
                p [bar]                                           AB1 / AB3       2      2      -      3      3
               20  K4291                            4             ACB             1      1      -      2      2
               18                                   3
               16                                                 ADB             1      1      -      1      1
               14                                   2
               12                                   1             BEA             1      1      4      2      2
               10
               8
               6
               4
               2                                                  Q  = f (Q)  Leakage volume flow characteristics
               0                                                   L
                 0  5  10  15  20  25  30  35  40  45  50  Q [l/min]        P → T

                                                                     Q  [cm /min]
                                                                          3
                                                                      L
                                                                   300  K4199
                                                                   250
            Note!    With the L15 / L17 execution for ambient temperatures                               BEA
                     up to 70 °C, the  performance specifications have been   200
                     evaluated with an ambient temperature of 50 °C  150                                 AB1 / AB2
                                                                   100                                   AB3
            Attention!  For valves for the temperature ranges „-40 °C to…”   50                          ACB / ADB
                     (Z604) the leakage volume flow can be up to eight times   0                           p [bar]
                     higher.                                          0    50  100  150  200  250  300  350





                               www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 23 12  1.3-34S E
                                                                                                            Page 215
   210   211   212   213   214   215   216   217   218   219   220