Page 368 - Softbound_Edition_19_en
P. 368
Proportional spool valve
Proportional spool valve Proportional spool valve
TYPE CODE PERFORMANCE SPECIFICATIONS
2
WD P F A06 - - / - # Oil viscosity u = 30 mm /s
Spool valve, direct operated Q = f (p) Volume flow pressure characteristics Q = f (p) Volume flow pressure characteristics
I = I I = I
Proportional G G
ACB-S, AC1-S, CB2-S ADB-V
Flange construction Q [l/min] Q [l/min]
50 K1115 50 K1116
International standard interface ISO, NG6 Q N = 32 l/min
40 40
Designation of symbols acc. to table 30 30 Q N = 32 l/min
Q N = 16 l/min Q N = 16 l/min
Nominal volume flow rate Q N 5 l/min 5 16 l/min 16 20 20
10 l/min 10 32 l/min 32 10 Q N = 10 l/min 10 Q N = 10 l/min
Q N = 5 l/min
Q N = 5 l/min
Nominal voltage U 12 VDC G12 0 0 50 100 150 200 250 300 350 p [bar] 0 0 50 100 150 200 250 300 350 p [bar]
N
24 VDC G24
without coil X5
Slip-on coil Metal housing, round W ∆p = f (Q) Pressure drop volume flow characteristics ∆p = f (Q) Pressure drop volume flow characteristics
Metal housing, square M
I = I G I = I G
Connection execution Connector socket EN 175301-803 / ISO 4400 D ACB-S, AC1-S, CB2-S ADB-V
Connector socket AMP Junior-Timer J p [bar] p [bar]
Connector Deutsch DT04 - 2P G 35 K1111 Q = 5 l/min Q = 10 l/min Q = 16 l/min 35 K1111 Q = 5 l/min Q = 10 l/min Q = 16 l/min
N
N
N
N
N
N
30 30
Sealing material NBR 25 25
FKM (Viton) D1
20 20
15 Q = 32 l/min 15 Q = 32 l/min
N
N
Manual override Integrated 10 10
Push-button HF1
Spindle HS1 5 5
0 0
0 4 8 12 16 20 24 28 32 Q [l/min] 0 4 8 12 16 20 24 28 32 Q [l/min]
Surface protection Standard
Zinc-nickel K8
Design index (subject to change) Q = f (I) Volume flow adjustment characteristics Q = f (I) Volume flow adjustment characteristics
1.10-77
∆p = 10 bar ∆p = 10 bar
ACB-S, AC1-S, CB2-S ADB-V
Q [l/min] Q [l/min]
30 K1113 Q = 32 l/min 30 K1114 Q = 32 l/min
N
ELECTRICAL SPECIFICATIONS HYDRAULIC SPECIFICATIONS 25 N 25
Protection class Connection execution D: IP65 Working pressure p = 350 bar 20 = 16 l/min 20
max
N
Connection execution J: IP66 Tank pressure p T max = 250 bar 15 Q N 15 Q = 16 l/min
N
Connection execution G: IP67 and IP69K Maximum volume flow Q = 42 l/min, see characteristics 10 Q N = 10 l/min 10 Q = 10 l/min
max
N
N
Relative duty factor 100 % DF Nominal volume flow Q = 5 l/min, 10 l/min, 16 l/min, 32 l/min 5 Q = 5 l/min 5 Q = 5 l/min
N
Standard nominal 12 VDC, 24 VDC Leakage oil On request 0 -100 -80 -60 -40 -20 0 20 40 60 80 100 l [%] 0 -100 -80 -60 -40 -20 0 20 40 60 80 100 l [%]
voltage Hysteresis ≤ 5 % at optimal dither signal
Limiting current at I = 930 mA (U = 24 VDC) Fluid Mineral oil, other fluid on request
N
G
50 °C I = 1690 mA (U = 12 VDC)
2
2
G N Viscosity range 12 mm /s…320 mm /s Note! All values were measured over two control edges. The
Note! Other electrical specifications see data sheet 1.1-182 Temperature range -25…+70 °C (NBR) connections A and B were short-circuited.
(slip-on coil W) and 1.1-181 (slip-on coil M) fluid -20…+70 °C (FKM)
Contamination Class 18 / 16 / 13
efficiency
Filtration Required filtration grade ß 6…10 ≥ 75,
see data sheet 1.0-50
www.wandfluh.com Illustrations are not binding Data subject to change 2/5 Edition: 20 23 1.10-77 E www.wandfluh.com Illustrations are not binding Data subject to change 3/5 Edition: 20 23 1.10-77 E
Page 368