Page 520 - Softbound_Edition_19_en
P. 520

Poppet valve



                                                                                                                                   Solenoid operated poppet valve cartridge
                                                                                                                                    ◆  solenoid actuated                                M22 x 1,5
                                                                                                                                    ◆  pilot operated                                   ISO 7789
                                                                                                                                    ◆  normally open and normally closed                x II 2 G Ex db IIC T6, T4
                                                                                                                                    ◆  2/2-way                                          x II 2 D Ex tb III C T80 °C, T130 °C
                                                                                                                                    ◆  Q  = 80 l/min                                    x I M2 Ex db I Mb
                                                                                                                                       max
                                                                                                                                    ◆  p   = 350 bar
                                                                                                                                       max
                                                                                                                                                                                        Class I Division 1
                                                                                                                                                                                        Class I Zone 1



                                                                                                                                   DESCRIPTION                                          APPLICATION
                                                                                                                                   Pilot operated 2/2-way solenoid poppet valve in screw-in cartridge   These  valves  are  suitable  for  applications  in  explosion-hazard
                                                                                                                                   construction for cavity according to ISO 7789. The CB execution  is   areas, open cast and also in mines. Poppet valves are used where
                                                                                                                                   closed in the energised position, the BC execution in the de-energi-  tight closing functions of the valve are essential like leakage-free
                                                                                                                                   sed position. In this, the main spool closes practically leakage-free   load  holding,  clamping  or  gripping.  For  machining  the  cartridge
                                                                                                                                   by means of the applied pressure. In the opposite flow direction, the   cavity in steel and aluminum blocks, cavity tools are available (hire
                                                                                                                                   valve  opens  after  reaching  the  opening  pressure.  The  pressure   or purchase). Please refer to the data sheets in register 2.13.

                                                                                                                                   tight encapsulated Ex-protection solenoid coil prevents an explo-
                                                                                                                                   sion on the inside penetrating to the outside as well as an ignitable

                                                                                                                                   surface temperature.




                                                                                                                                   CERTIFICATES                                         ACTUATION

                                                                                                                                             Surface  Mining   Standard      Z604        Actuation          Switching solenoid, wet pin push + pull
                                                                                                                                                              -25 °C to…  -40 °C to…                        type, pressure tight
                                                                                                                                    ATEX       x       x          x           x          Execution          MKY45 / 18x60 (data sheet 1.1-183)
                                                                                                                                                                                                            MKU45 / 18x60 (data sheet 1.1-184)
                                                                                                                                    IECEx      x       x          x           x
                                                                                                                                    CCC        x       x          x           x          Connection         Cable gland for cable Ø 6,5…14 mm
                                                                                                                                    EAC        x       x          x           x         Attention!  The UL execution is always supplied without cable
                                                                                                                                    Australia  x       x          x           x                  gland
                                                                                                                                    MA                 x          x
                                                                                                                                    UL / CSA   x                  x           x
                                                                                                                                   The certificates can be found on www.wandfluh.com









                                                                                                                                   SYMBOL
                                                                                                                                   „Normally closed“ BC                                 „Normally open“ CB
                                                                                                                                                 2                                                    2

                                                                                                                                     a                  b                                a                   b
                                                                                                                                                 1                                                    1










                                                                                                                                                   www.wandfluh.com  Illustrations are not binding  Data subject to change  1/4  Edition: 21 18  1.11-2084 E