Page 226 - Softbound_Edition_19_en
P. 226

Solenoid operated spool valve
                                                                                Solenoid operated spool valve                                                                                                Solenoid operated spool valve


       TYPE CODE                                                                                                                   ACTUATION                                            MANUAL OVERRIDE
                                                          W  W  M  F  A04  -     -     /        -           #                       Actuation          Switching solenoid, wet pin push type,   ◆  Integrated (–) Actuation pin integrated in the armature tube.
       Spool valve, soft switching                                                                                                                     pressure tight                     Actuation by pressing the pin
                                                                                                                                    Execution          V.E37 / 19 x 50 (Data sheet 1.1-168)  ◆  Push-button (HF1) Integrated in the knurled nut. Actuation by
       Slip-on coil, Medium                                                                                                                                                               pressing the push-button
                                                                                                                                                       N.S35 / 19 x 50 (Data sheet 1.1-175)
       Flange construction                                                                                                          Connection         Connector socket EN 175301 – 803  ◆  Spindle (HS1) Integrated in the knurled nut. Actuation by turning
                                                                                                                                                                                          the spindle (continuously variable valve actuation)
                                                                                                                                                       Connector socket AMP Junior-Timer
       Mounting interface acc. to Wandfluh standard, NG4-Mini                                                                                                                           Attention!  The actuation of the manual override is possible up to a
                                                                                                                                                       Connector Deutsch DT04 – 2P
                                                                                                                                                                                                 tank pressure of:
       Designation of symbols acc. to table                                                                                                                                                      40 bar Integrated (–)
                                                                                                                                                                                                 40 bar Push-button (HF1)
       Nominal voltage U      12 VDC    G12       115 VAC   R115                                                                                                                                 100 bar Spindle (HS1)
                   N
                              24 VDC    G24       230 VAC   R230
                              without coil   X5
       Slip-on coil           Metal housing, round with one-sided collar   V   (only G12 and G24)
                              Metal housing, square with one-sided collar   N
                                                                                                                                   PERFORMANCE SPECIFICATIONS
       Connection execution   Connector socket EN 175301-803 / ISO 4400   D                                                                         2
                              Connector socket AMP Junior-Timer   J   (only for U  ≤ 75 VDC)                                       Oil viscosity u = 30 mm /s
                                                                        N
                              Connector Deutsch DT04 - 2P    G   (only for U  ≤ 75 VDC)                                             p = f (Q)  Performance limits                        Q  = f (Q)  Leakage volume flow characteristics
                                                                        N
                                                                                                                                                                                          L
                                                                                                                                              Measured with nominal voltage -10 %                  per control edge
       Sealing material       NBR
                              FKM (Viton)                   D1                                                                          p [bar]                                             Q [cm /min]
                                                                                                                                                                                                3
                                                                                                                                     350  K1035                             AB1 / AB2      60  K1037
                                                                                                                                                                            ACB
       Manual override        Integrated                                                                                             300                                    ADB            50
                              Push-button                   HF1                                                                      250
                              Spindle                       HS1                                                                      200                                                   40
                                                                                                                                     150                                                   30
       Orifice diameter       Ø 0.3 mm (Standard)                                                                                    100                                                   20
                                                                                                                                      50                                                   10
       Design index (subject to change)                                                                                                0                                                    0
       1.4-13                                                                                                                            0       5       10       15      20  Q [l/min]      0       50      100      150     200 p [bar]

                                                                                                                                    Δp = f (Q)  Pressure drop volume flow characteristics                       Volume flow direction
       ELECTRICAL SPECIFICATIONS                           COMMISSIONING
                                                                                                                                       p [bar]                                           Symbol         P - A  P - B  P - T  A - T  B - T
       Protection class   Connection execution D: IP65     Attention!    When commissioning, the valve must be vented under           20  K1036                                          AB1 / AB2       3      3       -      3      3
                          Connection execution J: IP66              pressure (max. two rotations of screw E).                                                              3             ACB / AC1 / CB2  2     2       -      2      2
                          Connection execution G: IP67 and IP69K                                                                      15                                   2
       Relative duty factor  100 % DF                                                                                                 10                                   1             ADB / AD1 / DB2   3    3       -      1      1
       Switching frequency  Since switching is damped and slow,                                                                       5
                          switching frequency is of secondary   STANDARDS
                          importance.                       Mounting interface   Wandfluh standard                                    0                                     Q [l/min]
       Service life time  10  (number of switching cycles,                                                                              0       5        10      15       20
                            7
                          theoretically)                    Solenoids            DIN VDE 0580
       Voltage tolerance  ± 10 % with regard to nominal voltage  Connection execution D  EN 175301 – 803                                      Switching  times, influence of the soft switching     Switching  times, influence of the soft switching
       Standard nominal   12 VDC, 24VDC, 115 VAC, 230 VAC   Protection class     EN 60 529                                                    Solenoid energised                                   Solenoid deenergised
       voltage            AC = 50 to 60 Hz, rectifier integrated in   Contamination efficiency  ISO 4406                                      Measured with WWMFA04-ACB-G24 compared               Measured with WWMFA04-ACB-G24 compared
                          the connector socket                                                                                                with WDMFA04-ACB-G24  at Q = 10 l/min                with WDMFA04-ACB-G24 at Q = 10 l/min
       Note!   Other electrical specifications see data sheet 1.1-168                                                                   U [V]                                                U [V]
               (slip-on coil V) and 1.1-175 (slip-on coil N)                                                                          24                                                   24
                                                                                                                                       0                                                    0
                                                                                                                                        p  [bar]                                            p  [bar]
                                                                                                                                                                                             E
                                                                                                                                        E
                                                                                                                                     100  K1049_e                                         100  K1050_e
                                                                                                                                      80            Soft-switching valve                   80
       SURFACE TREATMENT                                   SEALING MATERIAL                                                           60            Standard valve                         60              Standard valve
       ◆  The valve body is painted with a two component paint  NBR or FKM (Viton) as standard, choice in the type code               40                                                   40             Soft-switching valve
                                                                                                                                      20
                                                                                                                                                                                           20
       ◆  The screw plug, the slip-on coil and the armature tube are                                                                   0                                                    0
         zinc-nickel coated                                                                                                              0    0    0,1   0,2   0,3   0,4  0,5 t [s]           0    0    0,1   0,2   0,3  0,4   0,5 t [s]



                           www.wandfluh.com  Illustrations are not binding  Data subject to change  2/4  Edition: 22 13  1.4-13 E                      www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 22 13  1.4-13 E