Page 510 - Softbound_Edition_19_en
P. 510

SVEPM20



                                                                                                                                   Solenoid operated poppet valve cartridge
                                                                                                                                    ◆  solenoid operated                                M20 x 1,5
                                                                                                                                    ◆  pilot operated
                                                                                                                                    ◆  normally closed
                                                                                                                                    ◆  2/2-way
                                                                                                                                    ◆  Q  = 40 l/min
                                                                                                                                       max
                                                                                                                                    ◆  p   = 350 bar
                                                                                                                                       max

                                                                                                                                   DESCRIPTION                                          APPLICATION
                                                                                                                                   Pilot operated 2/2-way solenoid poppet valve in screw-in cartridge   Poppet valves are used where tight closing functions of the valve
                                                                                                                                   design for cavity according to Wandfluh standard. In case of the BC   are essential like leakfree load holding, clamping or gripping. The




                                                                                                                                   execution, the valve is closed in the de-energised position.           poppet valve cartridge is mainly used in the mobile and stationary
                                                                                                                                                                                        block construction.




                                                                                                                                   SYMBOL
                                                                                                                                   „Normally closed“ BC
                                                                                                                                                 2
                                                                                                                                     a                  b
                                                                                                                                                 1

                                                                                                                                   TYPE CODE
                                                                                                                                                                                                                   S  V  E  PM20  -     -  X5  #
                                                                                                                                    Poppet valve

                                                                                                                                    Pilot operated
                                                                                                                                    Solenoid

                                                                                                                                    Screw-in cartridge M20 x 1,5
                                                                                                                                    2/2 way, «normally closed»       BC

                                                                                                                                    Without coil                     (The coil has to be ordered separately)
                                                                                                                                    Design index (subject to change)
                                                                                                                                    1.11-208A
                                                                                                                                   GENERAL SPECIFICATIONS                               HYDRAULIC SPECIFICATIONS
                                                                                                                                    Designation        2/2-way poppet valve              Working pressure   p   = 350 bar
                                                                                                                                                                                                             max
                                                                                                                                    Construction       Pilot operated                    Maximum volume flow  Q   = 40 l/min, see characteristics
                                                                                                                                                                                                              max
                                                                                                                                    Mounting           Screw-in cartridge type           Leakage volume flow  Seat tight, max. 5 drops / min at p
                                                                                                                                                                                                                                   max
                                                                                                                                    Nominal size       M20 x 1,5                         Fluid              Mineral oil, other fluid on request
                                                                                                                                    Actuation          Switching solenoid                Viscosity range    8 mm /s…420 mm /s
                                                                                                                                                                                                                        2
                                                                                                                                                                                                               2
                                                                                                                                    Ambient temperature  -30…+110 °C                     Temperature range   -20…+70 °C
                                                                                                                                    Weight             0,12 kg                           fluid
                                                                                                                                    MTTFd              150 years                         Contamination      Class 20 / 18 / 14
                                                                                                                                                                                         efficiency
                                                                                                                                                                                         Filtration         Required filtration grade ß 10…16 ≥ 75,
                                                                                                                                                                                                            see data sheet 1.0-50





                                                                                                                                   SURFACE TREATMENT                                    MANUAL OVERRIDE
                                                                                                                                    ◆  The armature tube and the external parts of the cartridge body   None
                                                                                                                                      are zinc coated



                                                                                                                                                   www.wandfluh.com  Illustrations are not binding  Data subject to change  1/2  Edition: 16 38  1.11-208A E