Page 608 - Softbound_Edition_19_en
P. 608
Poppet valve
Poppet valve Poppet valve
DIMENSIONS Solenoid operated poppet valve
3/2-; 2/2-way 3/2-; 2/2-way NG6
Flange construction
9.5 2/2-, 3/2- and 3/4-way ISO 4401-03
110 5.5 ◆
MD=5.2Nm ◆ normally open and normally closed x II 2 G Ex db IIC T6, T4
Q = 40 l/min
5.5 ◆ max x II 2 D Ex tb III C T80 °C, T130 °C
101 E ◆ p = 350 bar x I M2 Ex db I Mb
max
32.5 35 38 Class I Division 1
31 15 Class I Zone 1
12
12 17 18 10 18 50 70 40 60 50 10
MD= 9Nm MD=2.6Nm 156 B..22040b
156 B..32040b
60 8 DESCRIPTION APPLICATION
91 54 10 HYDRAULIC CONNECTION Direct operated 2/2-, 3/2 and 3/4-way solenoid poppet valve in These valves are suitable for applications in explosion-hazard
146 B..22041a flange construction. By means of the pressure tight switching sole- areas, open cast and also in mines. Poppet valves are used where
156 B..32041a 28 noid, the poppet valve spool is opened or closed acting against the tight closing functions of the valve are essential like leakage-free
E = Air bleed screw 14 spring. Due to the poppet spool construction with pressure load holding, clamping or gripping.
Dimensions of the solenoid coil see data sheet 1.1-183 and 1.1-184 compensation on both sides, the flow through the valve is possible
The distance plate BDP4/12 has to be ordered separately P in both directions. The metallically sealing seat closes the valve
3/4-way A B virtually leak free. The pressure tight encapsulated Ex-protection
14 27 solenoid coil prevents an explosion on the inside penetrating to the
T T0 outside as well as an ignitable surface temperature.
CERTIFICATES ACTUATION
MANUAL OVERRIDE
Screw plug (HB0), no actuation possible Surface Mining Standard Z604 Z591 Actuation Switching solenoid, wet pin push type,
Optionally: HB4,5, HN(K) or HG(K) -25 °C -40 °C -60 °C pressure tight
→ See data sheet 1.1-311 to… to… to… Execution MKY45 / 18x60 (data sheet 1.1-183)
10 50 ATEX x x x x x MKU45 / 18x60 (data sheet 1.1-184)
82 ACCESSORIES IECEx x x x x x Connection Cable gland for cable Ø 6,5…14 mm
266 Fixing screws Data sheet 1.0-60
Threaded subplates Data sheet 2.9-05 CCC x x x x x Attention! The UL execution is always supplied without cable
gland
PARTS LIST Multi-station subplates Data sheet 2.9-45 EAC x x x x x x x x x
Australia
Position Article Description Horizontal mounting blocks Data sheet 2.9-85 MA x x
10 263.6... Solenoid coil MKY45 / 18 x 60 Technical explanations Data sheet 1.0-100 UL / CSA x x x STANDARDS
12 154.2603 Knurled nut Ex M18 x 1,5 x 18 Hydraulic fluids Data sheet 1.0-50 Explosion protection Directive 2014 / 34 / EU (ATEX)
15 239.2033 Screw plug HB0 (incl. seal) Filtration Data sheet 1.0-50 The certificates can be found on www.wandfluh.com Flameproof enclosure EN / IEC 60079-1 / 31
17 160.2251 O-ring ID 25,07 x 2,62 (NBR) Relative duty factor Data sheet 1.1-430 Cable entry EN 60079-0, 1, 7, 15, 31
18 160.2170 O-ring ID 17,17 x 1,78 (NBR) INSTALLATION NOTES Mounting interface ISO 4401-03
40 057.4201 Cover Protection class EN 60 529
50 173.1450 Distance plate BDP4 / 12 Mounting type Flange mounting Contamination ISO 4406
3 fixing holes for efficiency
60 246.1113 Socket head screw M4 x 12 DIN 912 socket head screws M5 x 40 or M5 x 50
70 160.2052 O-ring ID 5,28 x 1,78 (NBR) (with distance plate BDP4/12)
160.6052 O-ring ID 5,28 x 1,78 (FKM) Mounting position Any, preferably horizontal SYMBOL
110 111.1080 Cable gland M20 x 1,5 Tightening torque Fixing screws M = 5,2 Nm (screw A.22060b A.22061a A.32060b A.32061a
D
quality 8.8, zinc coated) A A A A
M = 5 Nm knurled nut a b a b a b a b
COMMISSIONING Note! The length of the fixing screw depends on the base a b a b a b a b
D
Attention! When commissioning, the valve must be vented under material of the connection element. P P P T P T
pressure (max. two rotations of screw E). A.3406
A
The solenoid coil must only be put into operation, if the Attention! For stack assembly please observe the remarks in the ab
requirements of the operating instructions supplied are operating instructions a a o b b
observed to their full extent. In case of non-observance, P T
no liability is assumed.
Wandfluh AG Postfach CH-3714 Frutigen
Tel. +41 33 672 72 72 Fax +41 33 672 72 12 [email protected]
www.wandfluh.com Illustrations are not binding Data subject to change 4/4 Edition: 21 18 1.11-3132 E www.wandfluh.com Illustrations are not binding Data subject to change 1/4 Edition: 21 18 1.11-3143 E