Page 614 - Softbound_Edition_19_en
P. 614

Poppet valve
                                                                                                Poppet valve                                                                                                                 Poppet valve


       TYPE CODE                                                                                                                   PERFORMANCE SPECIFICATIONS
                                                                                                                                                    2
                                                                A  Exd     2  06     -     /     /     -        #                  Oil viscosity u = 30 mm /s
       International standard interface ISO                                                                                         p = f (Q)  Performance limits L15 / L17              P = f (Q)  Performance limits L9
                                                                                                                                              Measured with nominal voltage -10% at 50 °C          Measured with nominal voltage -10% at 40 °C
       Explosion-proof execution, Ex d
                                                                                                                                                                                                   Execution L9 90 °C on request
       2 way (connections)               2                                                                                              p [bar]                                              p [bar]
       3 way (connections)               3                                                                                           350  K0989              4                            350  K0990
                                                                                                                                     300                                     1            300                                     1
       2 switching positions                                                                                                                           3,6                   2
                                                                                                                                     250                                     6            250             7                       2
                                                                                                                                     200                                                  200                                     4
       Nominal size 6                                                                                                                                                        3
                                                                                                                                     150                           7                      150                                     3
       Normally closed   Solenoid on A-side                 1a                                                                       100           5                                      100        6    5             6
       Normally open     Solenoid on B-side                 0b                                                                        50                                                   50                        7
                                                                                                                                       0                                                    0
                                                                                                                                         0   5   10  15  20   25  30  35  40  Q [l/min]       0   5   10  15  20  25   30  35  40  Q [l/min]
       Nominal voltage U    12 VDC      G12    115 VAC      R115
                   N
                         24 VDC         G24    230 VAC      R230
                                                                                                                                                             Flow direction                                       Flow direction
                                               Ambient temperature up to:
       Nominal power P    9 W            L9    40 °C or 90 °C                                                                       Type           P - A    A - T    A - P    T - A      Type           P - A    A - T    A - P    T - A
                  N
                         15 W           L15    70 °C                                                                                AEXd22061a       1        -        6        -        AEXd22061a      1        -        6         -
                         17 W           L17    70 °C (only UL / CSA)
                                                                                                                                    AEXd22060b       1        -        3        -        AEXd22060b      1        -        3         -
       Certification     ATEX, IECEx, EAC, CCC                                                                                      AEXd32061a       1        2        5        1        AEXd32061a      1        2        5        1
                         Australia      AU     UL / CSA   UL   MA      MA
                                                                                                                                    AEXd32060b       1        4        7        1        AEXd32060b      1        4        7        1
       Sealing material /   NBR
       Temperature range   FKM (Viton)   D1
                         NBR -40 °C     Z604   (only with 15 W)
                                                                                                                                    Δp = f (Q)  Pressure drop volume flow characteristics  ELECTRICAL SPECIFICATIONS
       Stainless         with K8 coil   K9                                                                                                                                               Protection class   IP65 / 66 / 67
                         with K9 coil   K10    (not for UL execution)                                                                  p [bar]
                                                                                                                                      35  K0078                                          Relative duty factor  100 % DF
                                                                                                                                      30
       Design index (subject to change)                                                                                               25                                                 Switching frequency  12'000 / h
       1.11-3143S                                                                                                                                                                        Voltage tolerance  ± 10 % with regard to nominal voltage
                                                                                                                                      20
                                                                                                                                      15                                                 Standard nominal   12 VDC, 24VDC, 115 VAC, 230 VAC
       GENERAL SPECIFICATIONS                              HYDRAULIC SPECIFICATIONS                                                   10                                                 voltage            AC = 50 to 60 Hz ± 2 %, with built-in
                                                                                                                                       5                                                                    two-way rectifier
       Designation        2/2-, 3/2-way poppet valve        Working pressure   p  = 350 bar
                                                                                max                                                    0                                                 Standard nominal   9 W, 15 W, 17 W
       Construction       Direct operated                   Maximum volume flow  Q  = 40 l/min, see characteristic                       0   5  10   15  20  25  30   35  40  Q [l/min]  power
                                                                                max
       Mounting           Flange construction               Volume flow direction  Any (see characteristic)                                                                              Temperature class  Nominal power 9 W: T1…T6
       Nominal size       NG6 according to ISO 4401-03      Leakage oil        Poppet type, max. 0,05 ml / min (approx.            Note!    With the L15 / L17 execution for ambient temperatures           Nominal power 15 W / 17 W: T1…T4
       Actuation          Ex-protection switching solenoid                     1 drop / min) at 30 cSt                                      up to 70 °C, the  performance specifications have been
       Ambient temperature  Operation as T6                 Fluid              Mineral oil, other fluid on request                          evaluated with an ambient temperature of 50 °C  Note!  Other electrical specifications see data sheet 1.1-183
                                                                                                                                                                                                 and 1.1-184
                          -25…+40 °C (L9)                   Viscosity range    12 mm /s…320 mm /s                                  Attention!  Long periods of non-actuation can reduce the switching
                                                                                            2
                                                                                   2
                          Operation as T4                   Temperature range   Operation as T6                                             performance
                          -25…+90 °C (L9)                   fluid              NBR -25…+40 °C (L9)
                          -25…+70 °C (L15 / L17)                               FKM -20…+40 °C (L9)
                          -40…+70 °C (L15 / L17)                               Operation as T4
       Weight             3,3 kg                                               NBR -25…+70 °C (L9 or L15 / L17)                    SURFACE TREATMENT                                    SEALING MATERIAL
                                                                                                                                                                                        NBR or FKM (Viton) as standard, choice in the type code
                                                                                                                                   -The valve body, the cover and the socket head screws are made of
       MTTFd              150 years                                            FKM -20…+70 °C (L9 or L15 / L17)                    stainless steel
                                                                               NBR 872 -40…+70 °C (L15 / L17)
                                                            Contamination      Class 20 / 18 / 14                                  -The slip-on coil and the armature tube are zinc nickel coated  MANUAL OVERRIDE
                                                                                                                                   Optionally K10:
                                                            efficiency                                                             -The coil is made of stainless steel                 Screw plug (HB0), no actuation possible
                                                            Filtration         Required filtration grade ß 10…16 ≥ 75,                                                                  Optionally: HB6, HN(K) or HG(K)
                                                                               see data sheet 1.0-50                                                                                    → See data sheet 1.1-311

                                                                                                                                   VALVES INSTALLED
                                                                                                                                   The central functioning element is the poppet valve cartridge NG6, data sheet 1.11-2030.





                     www.wandfluh.com  Illustrations are not binding  Data subject to change  2/4  Edition: 21 18  1.11-3143S E                   www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 21 18  1.11-3143S E