Page 721 - Softbound_Edition_19_en
P. 721

Digital amplifier electronics PD3                                               Amplifier and controller electronics
                                                                                    Amplifier / controller electronics
 PD3-AMPLIFIER
            Integrated amplifier and controller
 Command value scaling  Solenoid driver  electronics
 Type IO-Link: The command value can only be specified via IO-Link.  A Pulse-Width-Modulated current output is available. A dither signal is   for proportional hydraulic valves
 Type analogue: The command value can be specified as a voltage, cur-  superimposed, whereby the dither frequency and the dither level are
 rent, digital, frequency or PWM signal.   separately adjustable. The minimum (Imin) and maximum (Imax) cur-  • Interface:  - analogue
 rent can be adjusted. The solenoid output can also be configurated as      - CANopen or J1939
 Ramp generator  switching solenoid output. In this case, a power reduction can be ad-     - Profibus DP
 Two linear ramps for up and down are available which can be adjusted   justed.  • 24 VDC or 12 VDC
 separately.
 Channel enabling  • Electronic card setting via PC (USB)
 Valve type  Enable can be configurated by means of the App:  • Optimisation of characteristic curve
 Adjustment possibilities: switching solenoid or proportional solenoid.  • on  L+
 • off  1
 X2-1
 Mode of operation «Command value unipolar/bipolar (1-Sol)»  • external (enable input with type analogue)  Description  Function  Application
 P24
 X2-2
 2
 Dependent on a command value signal (IO-Link, voltage, current,    • bus (with type IO-Link)  Wandfluh offers proportional valves with inte-  The actuation takes place via an analogue in-  The „DSV“ electronics are used by Wandfluh
 L-
 digital, frequency or PWM), the solenoid is controlled (e.g. 0….10V cor-  3  grated, intelligent electronics. With protection   terface or a fieldbus interface (CANopen/J1939   exclusively for proportional hydraulic valves.
 respond to 0….100 % command value, which again corresponds to   C/Q  4  class IP67 these valves are suitable for rough   or Profibus DP). The parameterisation takes   They are factory set and adjusted in order to
 Imin….Imax solenoid driver).  N24  ambient conditions. The term “Digital Smart   place by means of the free-of-charge parame-  guarantee the highest valve-to-valve reprodu-
 5          Valve” stands for digital amplifier or controller   trisation and diagnosis software “PASO” or via   cibility. The hydraulic valves have their appli-
            electronics requiring the smallest space. As a   the fieldbus interface.  cation where a good valve-to-valve reproduci-
            result of the compact construction, Wandfluh   “PASO” is a Windows program in the flow dia-  bility, a simple installation, convenient opera-
            is in the position to also offer miniature valves   gram style, which enables the intuitive adjust-  tion  and the highest precision are of great
            of the nominal size 4 in an optimum, slender   ment and storing of all variable parameters.   importance. The integrated controller reliefs
            design. In addition to this, Wandfluh as the only   The data remain saved in case of a power fai-  the machine control and operates the axis (po-
            manufacturer offers proportional screw-in cart-  lure and can also be reproduced and transfer-  sition, angle, pressure, etc.) in a closed con-
            ridges M22 and M33 with integrated electro-  red to other DSVs.       trol loop. The applications are in the industrial
            nics. The electronics are mounted onto a slip-  As an option, these valves are available with   as well as in the  mobile hydraulics for  the
 L+
 1          on coil.                           an integrated controller. As feedback value ge-  smooth control of hydraulic actuations.
 0 %   100 %   Command value  0..10V/0..+10V  X2-1  nerators sensors with voltage or current out-
 X2-2
 0 V   10 V  0/4..20mA  2                      puts can be directly connected. The available
 4 mA   20 mA   Analog value  L-  3            controller structures have been optimised for
 0 mA   20 mA  Dig.In                          applications with hydraulic actuators.
 5 Hz   5000 Hz   4
 5          TYPE CODE
                                                                -      M   E           -          #
 CONNECTION EXAMPLES
            Type designation according to type list,
            (derived from valve designation basic execution)
 Connection example IO-Link  Connection example analogue with stabilised output
            Example: BVPPM33 - 200
 L+  L+     Standard nominal voltage U N :    12 VDC     G12
 1  1                                    24 VDC         G24
 P24  X2-1  0..5V  X2-1
 2  X2-2    2  X2-2    Slip-on coil   Metal housing, square
 L-  L-
 3  3
 C/Q  P24, N24, X2  Dig.In
 4  el. isolated  4  Connection execution  Integrated electronics
 N24  from L+, L-, C/Q  Stab.Out
 5  5
            Hardware configuration:


            Analog command value signal   12-pole  A1   7-pole  D1   (0...+10V factory preset)


            Analog command value signal   12-pole  A2   7-pole  D2   (-10...+10V factory preset)


            Analog command value signal   12-pole  A3   7-pole  D3   (0...+20mA factory preset)


            Analog command value signal   12-pole  A4   7-pole  D4   (4...+20mA factory preset)
 WANDFLUH APP
            CANopen according to DSP-408       C1

            Profibus DP acc. to Fluid Power Technology  P1
            CAN J1939 (on request)          J1
 L+
 1
 0..10V/0..+10V  X2-1  Functions:
 X2-2
 0/4..20mA  2  Amplifier                                      no remark
 L-         Controller with current feedback value
 3
 Dig.In     signal (0…20 mA / 4…20 mA)                   R1
 4          Controller with voltage feedback value signal (0…10 V)      R2
 5
            Sealing material / manual override
            Design-Index (Subject  to change)
 L+
 1
 0..5V  X2-1
 X2-2
 Wandfluh AG   2  Tel.  +41 33 672 72 72   E-mail:  [email protected]   Illustrations not obligatory   Data sheet no.  Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  [email protected]   Illustrations not obligatory   Data sheet no.
 Postfach   L-  3  Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   1.13-66E 4/4   Postfach   Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   1.13-76E 1/10
 CH-3714 Frutigen     Edition 21 20  CH-3714 Frutigen                                                    Edition 21 20
 Dig.In
 4                                                                                                          Page 721
 Stab.Out
 5
   716   717   718   719   720   721   722   723   724   725   726